Consulting Firm
Marion, MA |
Site Investigation of Former Mill Site |
Performed sampling and analysis of Soil, Water, and Waste samples, in support of
a site investigation utilizing US EPA SW-846 and MA DEP methods.
The analyses include waste disposable parameters and field screening analysis
for total petroleum hydrocarbons.
|
Consulting Firm
Sandwich, MA |
Site Investigation for Airport |
Performed analysis of Soil, Water, and Waste samples in support of a investigation,
utilizing US EPA SW-846 and MA DEP Protocol. The analyses included organic
and inorganic tests. |
Consulting Firm
Providence, RI |
Suspected MGP Waste Disposal Site |
Performed analysis of samples from a suspected waste disposal site, in support of
an investigation, utilizing US EPA protocols and provided full data deliverable
packages with over a 99.5% acceptance rate by an independent data validator. |
Consulting Firm
Providence, RI |
Emergency Response for Gasoline Release |
Provided one (1) hour turnaround for the analysis of Volatile Organic Compounds
associated with a gasoline line that was breached during a weekend construction
project |
Consulting Firm
East Providence, RI |
Superfund Site |
Performed a 12 hour rapid turnaround analysis of groundwater samples to delineate
screening levels for monitoring well installations
|
Consulting Firm
Providence, RI |
Emergency Response for Mercury Release |
Provided personnel to perform field air monitoring and analysis for Mercury in private
homes, vehicles, hospital, schools, in response to a Mercury release.
|
Consulting Firm
Northern, MA |
Site Investigation of Semi-conductor Facility |
Performed analysis of soils and groundwater samples for Volatile & Semi-volatile
Organics, Metals, PCBs, Perchlorates, and Total Petroleum Hydrocarbons, in support
of a Site Investigation
|
Consulting Firm
Newport, RI |
Dredging Analysis for the construction of a Marina |
Performed sampling of dredge spoils from a floating drill platform for over three
weeks period. The samples were analyzed for Volatile Organics, PCBs, and Metals.
|
Utility
Providence, RI |
Wastewater Discharge |
Provided Operation and Maintenance including Confined Space Sampling for a Utility
compliance with their POTW requirements.The
analysis included Volatile, Semi-Volatile organics, Metals and various wet Chemistry
Parameters.
|
Utility
Providence, RI |
Emergency Response |
Performed PCB analysis on a rapid turn around time with results provided in 5 hours
in response to a transformer oil spill
|
|
Private Party |
Drinking Water Analysis |
Performed Volatile Organics Analysis of Drinking Water samples which prompted an
investigation of the contamination by a State regulatory agency.
|
Construction Firm
Warwick, RI |
Emergency Response due to Explosion |
Performed sampling and analysis of aqueous sample for Volatile Organics compounds
in support of an Explosion Investigation at a Construction site
|
Consulting Firm
Glastonbury, CT |
MGP sites
Scranton, PA |
Performed analysis of Soil, Water, and Waste samples in support of an investigation
of various MGP sites owned by a national utility company.
Samples were analyzed for various Organic and Inorganic compounds utilizing
US EPA SW-846 and PA DEP Protocol
|
Industrial Client
Lynn, MA |
Waste Characterization |
Performed analytical services for a Multi-year contract to provide waste characterization
analyses on a variety of materials to be disposed of.These included; Tyvek suits, batteries, oil, rags, paint, solvents, PCB wipes
and floor sweepings.
|
Industrial Client
Versailles, CT |
Landfill Ground Water monitoring and Effluent analysis |
Performed quarterly analysis of ground water samples including weekly effluent analysis
for a variety of contaminants, in compliance with a permit requirement.
|
Consulting Firm
Needham, MA |
Brownfields Redevelopment Project |
Performed a 3 year analytical program for an industrial site redevelopment project.
In Boston
. Soil and Water samples were analyzed using the MCP guidelines.
Some disposal parameters on excavated soils required rapid turnaround of
24 to 48 hours.
|
Consulting Firm
Merrimack, NH |
Industrial Plant Closure Investigation |
Performed analytical services in support of a closure investigation at a former
electroplating facility.Soil, aqueous,
concrete cores, oil and groundwater samples were analyzed for; Volatiles, PAH’s,
PCB’s, Cyanide, Metals, Hexavalent Chromium, TPH and TCLP parameters.
|
Consulting Firm
Warwick, RI |
City of Providence Brownfields Redevelopment Project |
Performed analytical services for an industrial site redevelopment project, in downtown
.Soil and groundwater samples were
analyzed to determine the extent of remediation required to ensure
public safety.
|
Consulting Firm
Manchester, NH |
Fort Devens MA |
Provided analytical services in support of an investigation and demolition contract
for the Army Corps of Engineers. Hundreds
of samples analyzed over a one month period for pesticides and disposal parameters.
|
Consulting Firm
Newburgh, NY |
USACE
Groton, CT |
Provided analytical services in support of a site investigation and remediation
project. Samples were analyzed for
various Organic and Inorganic compounds utilizing
US
EPA SW-846 protocols including providing USACE deliverables. |
Consulting Firm
Marlborough, MA |
Ottati and Goss Superfund Site
New Hampshire DACA27-99-D-0018 |
Provided analytical services in support of an onsite thermal treatment plant project
for the US EPA and Army Corps of Engineers.
Several thousand samples were analyzed on a 24 hour turn time over of 8 months.The primary contaminants of concern
were PCB’s and Volatile organics.
|
Consulting Firm
Marlborough, MA |
MMR AFCEE
Cape Cod, MA
F41264-01-D-8551 |
Provided analytical services for various Organic and Inorganic compounds including
physical parameters. The analyses were
performed in accordance with SW846 and ASTM protocols including providing AFCEE
ERPIRMS deliverables.
|
Consulting Firm
Southborough, MA |
Navy Contract
RI Nike Test Pilot Site |
Provided analytical services in support of a remediation site investigation
Samples were analyzed for various Organic
and Inorganic compounds utilizing US EPA SW-846 protocols including providing full
deliverables
|
Consulting Firm
Lawrence, MA |
Coast Guard
Weymouth, MA |
Provided analytical support for a site investigation in Weymouth
. Samples were analyzed for various
Organic and Inorganic compounds utilizing US EPA SW-846 protocols including providing
full deliverables
|
Consulting Firm
Manchester, NH |
Atlas Tack
MA |
Provided analytical testing services in support of an investigation and disposal contract under the US Army. Hundreds of samples analyzed over a 2 year period for pesticides and disposal parameters.
|
Consulting Firm
Portland, ME |
Fort Greene
Abandoned Rife Range RI |
Provided analytical testing services in support of an investigation and disposal contract with the US Army. Samples were analyzed for Lead, VOCs and SVOCs. Including SEDD and ERIS deliverables.
|
Consulting Firm
Lowel, MA |
Charlestown, RI
|
Provided analytical testing services in support of a remedial investigation and disposal contract with the US Army. Samples were analyzed for GRO, Lead VOCs, SVOCs and disposal parameters. Including SEDD deliverables.
|
Consulting Firm
Providence, RI |
BNAS ME
|
Provided analytical testing services in support of a remedial investigation contract with the US Navy and EPA. Samples were analyzed for disposal and confirmatory parameters.
|
Consulting Firm
Montpelier,VT |
Bucks Harbor, ME
|
Provided analytical testing services in support of a long term monitoring contract with the US Army Corps of Engineers. Samples were analyzed for VOCs by method 524.2, including a SEDD deliverable.
|
|
US Army |
Glenburn, ME
|
Provided analytical testing services in support of a long term monitoring program. Including full data packages and SEDD deliverables.
|
Naval Undersea
Warfare Center |
Various Projects
|
Provided analytical testing services in support of a long term monitoring programs.
|
Consulting Firm
Hamilton, NJ |
Chicopee Landfill
|
Performed PCB analysis on over 3000 soil samples. Up to 50 samples per day were extracted by method 3541 and analyzed by method 8082, in accordance with TSCA subpart Q requirements.
|
Consulting Firm
Newton, MA |
Southbridge Landfill |
Performed PCB analysis on 800 soil samples submitted over a 7 day period. The samples were extracted by method 3541 and analyzed by method 8082, in accordance with TSCA subpart Q requirements.
|
Consulting Firm
Worchester, MA |
Dartmouth Boat Yard |
Performed PCB analysis on 500 soil samples submitted over a 7 day period. The samples were extracted by method 3541 and analyzed by method 8082, in accordance with TSCA subpart Q requirements.
|
Consulting Firm
Wellesley, MA |
Boston Redevelopment Authority Project |
An industrial site in South Boston was characterized for PCB contamination under TSCA Guidelines. Approximately 1000 soil samples were analyzed to determine the extent of PCB remediation required to meet TSCA requirements.
|